EDMO

Fluke 1507 Insulation Resistance Tester

FLUKE

CALL FOR PRICING
Special order
EDMO#FLUKE 1507
MFR#FLUKE-1507

Need help placing an order?
Call 800-235-3300 or Contact Us

Product Description

The Fluke 1507 is a versatile, compact, handheld insulation tester for advanced industrial and electrical insulation testing. Its multiple test voltages make it the ideal tool for many troubleshooting, commissioning, and preventative maintenance applications. Additional features, like the remote probe, save both time and money especially when performing repetitive tests.

Features

Includes:

TL224 Test Leads, TP74 Test Probes, clips (red & black), holster and remote probe

Features:

  • Performs insulation tests from 0.01 MΩ to 2.0 GΩ
  • Includes live circuit detection to prevent insulation test if voltage >30 V is detected
  • Includes auto-discharge of capacitive voltage for added user protection
  • Measures AC/DC voltage from 0.1 V to 600 V and resistance from 0.01 Ω to 20.00 kΩ
  • Provides lo-ohms earth-bond continuity (200 mA)
  • Simplifies repetitive or hard-to-reach testing with the remote test probe
  • Saves battery power with auto power off
  • Presents results on a large, backlit display
  • Features CAT IV 600 V overvoltage category rating
  • Comes with remote probe, test leads, test probes, alligator clips and one-year warranty
  • Accepts optional Fluke TPAK magnetic hanging system to free your hands for other work
  • Runs on four AA alkaline batteries (NEDA 15 A or IEC LR6) for at least 1000 insulation tests

Specifications

Weight:
550 g (1.2 lb)

Dimensions:
5.0 x 10.0 x 20.3 cm (1.97 x 3.94 x 8.00 in)

IP rating:
IP40

Altitude:
Operating: 2000 m CAT IV 600 V, 3000 m CAT III 600 V
Non-operating (storage): 12,000 m

Vibration:
Random, 2 g, 5-500 Hz per MIL-PRF-28800F, Class 2 instrument

Shock:
1 meter drop per IEC 61010-1 2nd Edition (1 meter drop test, six sides, oak floor)

Maximum voltage applied to any terminal:
600 V AC rms or DC

AC/DC Voltage Measurement
Accuracy:
Range: 600.0 V
Resolution: 0.1 V
50 Hz to 400 Hz ± (% of Rdg + Digits): ±(2% + 3)

Input impedance:
3 MΩ (nominal), < 100 pF

Common mode rejection ratio (1 kΩ unbalanced):
> 60 dB at DC, 50 or 60 Hz

Overload protection:
600 V rms or DC

Earth Bond Resistance Measurement
Range/Resolution:
20.00 Ω : 0.01 Ω
200.0 Ω : 0.1 Ω
2000 Ω : 1.0 Ω
20.00 kΩ : 0.01 kΩ

Accuracy:
±(1.5% + 3)

Overload protection:
2 V rms or DC

Open circuit test voltage:
> 4.0 V, < 8 V

Short circuit current:
> 200.0 mA

Insulation Specifications
Measurement range:
0.01 MΩ to 10 GΩ

Test voltage:
50 V, 100 V, 250 V, 500 V, 1000 V

Test voltage accuracy:
+ 20%, - 0%

Short circuit current:
1 mA nominal

Auto discharge Discharge time:
< 0.5 second for C = 1 µF or less

Live circuit indicator:
Inhibit test if terminal voltage > 30 V prior to initialization of test

Maximum capacitive load:
Operable with up to 1 µF load

Measure accuracy:
50 V ±(3% + 5)
100 V ±(3% + 5)
250 V ±(1.5% + 5)
500 V ±(1.5% + 5)
1000 V ±(1.5% + 5) to 2000 MΩ, ±(10% + 3) above 2000 MΩ

Product Codes

  • Mfr Part No:FLUKE-1507
  • EDMO #:FLUKE 1507
  • Brand:FLUKE
  • Category:Wire & Cable Testers
  • ANSI:ANSI/ISA 82.02.01
  • ANSI:ANSI/ISA 82.02.01
  • CSA:CAN/CSA-C22.2 NO.61010-1-04
  • CSA:CAN/CSA-C22.2 NO.61010-1-04
  • ECCN:3a992
  • ECCN:3a992
  • SCHEDULE B CODE:9025.19.8080